Quantitative imaging of protein targets in the human brain with PET.
File(s) PMB_Topical_Review_Submitted.pdf (5.34 MB)
Accepted version
Author(s)
Gunn, RN
Slifstein, M
Searle, GE
Price, JC
Type
Journal Article
Abstract
PET imaging of proteins in the human brain with high affinity radiolabelled molecules has a history stretching back over 30 years. During this period the portfolio of protein targets that can be imaged has increased significantly through successes in radioligand discovery and development. This portfolio now spans six major categories of proteins; G-protein coupled receptors, membrane transporters, ligand gated ion channels, enzymes, misfolded proteins and tryptophan-rich sensory proteins. In parallel to these achievements in radiochemical sciences there have also been significant advances in the quantitative analysis and interpretation of the imaging data including the development of methods for image registration, image segmentation, tracer compartmental modeling, reference tissue kinetic analysis and partial volume correction. In this review, we analyze the activity of the field around each of the protein targets in order to give a perspective on the historical focus and the possible future trajectory of the field. The important neurobiology and pharmacology is introduced for each of the six protein classes and we present established radioligands for each that have successfully transitioned to quantitative imaging in humans. We present a standard quantitative analysis workflow for these radioligands which takes the dynamic PET data, associated blood and anatomical MRI data as the inputs to a series of image processing and bio-mathematical modeling steps before outputting the outcome measure of interest on either a regional or parametric image basis. The quantitative outcome measures are then used in a range of different imaging studies including tracer discovery and development studies, cross sectional studies, classification studies, intervention studies and longitudinal studies. Finally we consider some of the confounds, challenges and subtleties that arise in practice when trying to quantify and interpret PET neuroimaging data including motion artifacts, partial volume effects, age effects, image registration and normalization, input functions and metabolites, parametric imaging, receptor internalization and genetic factors.
Date Issued
2015-10-29
Date Acceptance
2015-05-05
Citation
Physics in Medicine and Biology, 2015, 60 (22), pp.R363-R411
ISSN
1361-6560
Publisher
IOP Publishing: Hybrid Open Access
Start Page
R363
End Page
R411
Journal / Book Title
Physics in Medicine and Biology
Volume
60
Issue
22
Copyright Statement
©2015 IOP Publishing Ltd.
Publication Status
Published
