Interferon gamma release assays for diagnostic evaluation of active tuberculosis (IDEA): test accuracy study and economic evaluation
File(s)Takwoingi HTA 2019.pdf (1.87 MB)
Published version
Author(s)
Type
Journal Article
Abstract
Background
Interferon gamma release assays (IGRAs) are blood tests recommended for the diagnosis of tuberculosis (TB) infection. There is currently uncertainty about the role and clinical utility of IGRAs in the diagnostic workup of suspected active TB in routine NHS clinical practice.
Objectives
To compare the diagnostic accuracy and cost-effectiveness of T-SPOT.TB® (Oxford Immunotec, Abingdon, UK) and QuantiFERON® TB GOLD In-Tube (Cellestis, Carnegie, VIC, Australia) for diagnosis of suspected active TB and to estimate the diagnostic accuracy of second-generation IGRAs.
Design
Prospective within-patient comparative diagnostic accuracy study.
Setting
Secondary care.
Participants
Adults (aged ≥ 16 years) presenting as inpatients or outpatients at 12 NHS hospital trusts in London, Slough, Oxford, Leicester and Birmingham with suspected active TB.
Interventions
The index tests [T-SPOT.TB and QuantiFERON GOLD In-Tube (QFT-GIT)] and new enzyme-linked immunospot assays utilising novel Mycobacterium tuberculosis antigens (Rv3615c, Rv2654, Rv3879c and Rv3873) were verified against a composite reference standard applied by a panel of clinical experts blinded to IGRA results.
Main outcome measures
Sensitivity, specificity, predictive values and likelihood ratios were calculated to determine diagnostic accuracy. A decision tree model was developed to calculate the incremental costs and incremental health utilities [quality-adjusted life-years (QALYs)] of changing from current practice to using an IGRA as an initial rule-out test.
Results
A total of 363 patients had active TB (culture-confirmed and highly probable TB cases), 439 had no active TB and 43 had an indeterminate final diagnosis. Comparing T-SPOT.TB and QFT-GIT, the sensitivities [95% confidence interval (CI)] were 82.3% (95% CI 77.7% to 85.9%) and 67.3% (95% CI 62.1% to 72.2%), respectively, whereas specificities were 82.6% (95% CI 78.6% to 86.1%) and 80.4% (95% CI 76.1% to 84.1%), respectively. T-SPOT.TB was more sensitive than QFT-GIT (relative sensitivity 1.22, 95% CI 1.14 to 1.31; p < 0.001), but the specificities were similar (relative specificity 1.02, 95% CI 0.97 to 1.08; p = 0.3). For both IGRAs the sensitivity was lower and the specificity was higher for human immunodeficiency virus (HIV)-positive than for HIV-negative patients. The most promising novel antigen was Rv3615c. The added value of Rv3615c to T-SPOT.TB was a 9% (95% CI 5% to 12%) relative increase in sensitivity at the expense of specificity, which had a relative decrease of 7% (95% CI 4% to 10%).
The use of current IGRA tests for ruling out active TB is unlikely to be considered cost-effective if a QALY was valued at £20,000 or £30,000. For T-SPOT.TB, the probability of being cost-effective for a willingness to pay of £20,000/QALY was 26% and 21%, when patients with indeterminate test results were excluded or included, respectively. In comparison, the QFT-GIT probabilities were 8% and 6%. Although the use of IGRAs is cost saving, the health detriment is large owing to delay in diagnosing active TB, leading to prolonged illness. There was substantial between-patient variation in the tests used in the diagnostic pathway.
Limitations
The recruitment target for the HIV co-infected population was not achieved.
Conclusions
Although T-SPOT.TB was more sensitive than QFT-GIT for the diagnosis of active TB, the tests are insufficiently sensitive for ruling out active TB in routine clinical practice in the UK. Novel assays offer some promise.
Future work
The novel assays require evaluation in distinct clinical settings and in immunosuppressed patient groups.
Funding
This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and the NIHR Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK.
Interferon gamma release assays (IGRAs) are blood tests recommended for the diagnosis of tuberculosis (TB) infection. There is currently uncertainty about the role and clinical utility of IGRAs in the diagnostic workup of suspected active TB in routine NHS clinical practice.
Objectives
To compare the diagnostic accuracy and cost-effectiveness of T-SPOT.TB® (Oxford Immunotec, Abingdon, UK) and QuantiFERON® TB GOLD In-Tube (Cellestis, Carnegie, VIC, Australia) for diagnosis of suspected active TB and to estimate the diagnostic accuracy of second-generation IGRAs.
Design
Prospective within-patient comparative diagnostic accuracy study.
Setting
Secondary care.
Participants
Adults (aged ≥ 16 years) presenting as inpatients or outpatients at 12 NHS hospital trusts in London, Slough, Oxford, Leicester and Birmingham with suspected active TB.
Interventions
The index tests [T-SPOT.TB and QuantiFERON GOLD In-Tube (QFT-GIT)] and new enzyme-linked immunospot assays utilising novel Mycobacterium tuberculosis antigens (Rv3615c, Rv2654, Rv3879c and Rv3873) were verified against a composite reference standard applied by a panel of clinical experts blinded to IGRA results.
Main outcome measures
Sensitivity, specificity, predictive values and likelihood ratios were calculated to determine diagnostic accuracy. A decision tree model was developed to calculate the incremental costs and incremental health utilities [quality-adjusted life-years (QALYs)] of changing from current practice to using an IGRA as an initial rule-out test.
Results
A total of 363 patients had active TB (culture-confirmed and highly probable TB cases), 439 had no active TB and 43 had an indeterminate final diagnosis. Comparing T-SPOT.TB and QFT-GIT, the sensitivities [95% confidence interval (CI)] were 82.3% (95% CI 77.7% to 85.9%) and 67.3% (95% CI 62.1% to 72.2%), respectively, whereas specificities were 82.6% (95% CI 78.6% to 86.1%) and 80.4% (95% CI 76.1% to 84.1%), respectively. T-SPOT.TB was more sensitive than QFT-GIT (relative sensitivity 1.22, 95% CI 1.14 to 1.31; p < 0.001), but the specificities were similar (relative specificity 1.02, 95% CI 0.97 to 1.08; p = 0.3). For both IGRAs the sensitivity was lower and the specificity was higher for human immunodeficiency virus (HIV)-positive than for HIV-negative patients. The most promising novel antigen was Rv3615c. The added value of Rv3615c to T-SPOT.TB was a 9% (95% CI 5% to 12%) relative increase in sensitivity at the expense of specificity, which had a relative decrease of 7% (95% CI 4% to 10%).
The use of current IGRA tests for ruling out active TB is unlikely to be considered cost-effective if a QALY was valued at £20,000 or £30,000. For T-SPOT.TB, the probability of being cost-effective for a willingness to pay of £20,000/QALY was 26% and 21%, when patients with indeterminate test results were excluded or included, respectively. In comparison, the QFT-GIT probabilities were 8% and 6%. Although the use of IGRAs is cost saving, the health detriment is large owing to delay in diagnosing active TB, leading to prolonged illness. There was substantial between-patient variation in the tests used in the diagnostic pathway.
Limitations
The recruitment target for the HIV co-infected population was not achieved.
Conclusions
Although T-SPOT.TB was more sensitive than QFT-GIT for the diagnosis of active TB, the tests are insufficiently sensitive for ruling out active TB in routine clinical practice in the UK. Novel assays offer some promise.
Future work
The novel assays require evaluation in distinct clinical settings and in immunosuppressed patient groups.
Funding
This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and the NIHR Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK.
Date Issued
2019-05-01
Date Acceptance
2016-09-01
Citation
Health Technology Assessment, 2019, 23 (23)
ISSN
1366-5278
Publisher
NIHR Journals Library
Journal / Book Title
Health Technology Assessment
Volume
23
Issue
23
Copyright Statement
© 2019 Queen’s Printer and Controller of HMSO. This work was produced by Takwoingi et al. under the terms of a commissioning contract issued by the Secretary of State for Health and Social Care. This issue may be freely reproduced for the purposes of private research and study and extracts (or indeed, the full report) may be included in professional journals provided that suitable acknowledgement is made and the reproduction is not associated with any form of advertising. Applications for commercial reproduction should be addressed to: NIHR Journals Library, National Institute for Health Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK.
Sponsor
National Institute for Health Research
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000468859500001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Grant Number
08/106/02
Subjects
Science & Technology
Life Sciences & Biomedicine
Health Care Sciences & Services
GOLD IN-TUBE
SKIN-TEST
LOGISTIC-REGRESSION
LATENT TUBERCULOSIS
LIKELIHOOD RATIOS
TB
UTILITY
PULMONARY
SENSITIVITY
EXTRAPULMONARY
Publication Status
Published
Date Publish Online
2019-05-01