Switching from flash glucose monitoring to continuous glucose monitoring on hypoglycemia in adults with type 1 diabetes at high hypoglycemia risk: the extension phase of the I HART CGM study
File(s)
Author(s)
Reddy, Monika
Jugnee, Narvada
Anantharaja, Sinthuka
Oliver, Nick
Type
Journal Article
Abstract
Background: The I HART CGM study showed that real-time continuous glucose monitoring (RT-CGM) has greater beneficial impact on hypoglycemia than intermittent flash glucose monitoring (flash) in adults with type 1 diabetes (T1D) at high risk. The impact of continuing RT-CGM or switching from flash to RT-CGM for another 8 weeks was then evaluated.
Methods: Prospective randomized parallel group study with an extension phase. After a 2-week run-in with blinded CGM, participants were randomized to either RT-CGM or flash for 8 weeks. All participants were then given the option to continue with RT-CGM for another 8 weeks. Glycemic outcomes at 8 weeks are compared with the 16-week endpoint.
Results: Forty adults with T1D on intensified multiple daily insulin injections and with impaired awareness of hypoglycemia or a recent episode of severe hypoglycemia were included (40% female, median [IQR] age 49.5 [37.5–63.5] years, diabetes duration 30.0 [21.0–36.5] years, HbA1c 56 [48–63] mmol/mol, and Gold Score 5 [4–5]), of whom 36 completed the final 16-week extension. There was a significant reduction in percentage time in hypoglycemia (<3.0 mmol/L) in the group switching from flash to RT-CGM (from 5.0 [3.7–8.6]% to 0.8 [0.4–1.9]%, P = 0.0001), whereas no change was observed in the RT-CGM group continuing with the additional 8 weeks of RT-CGM (1.3 [0.4–2.8] vs. 1.3 [0.8–2.5], P = 0.82). Time in target (3.9–10 mmol/L) increased in the flash group after switching to RT-CGM (60.0 [54.5–67.8] vs. 67.4 [56.3–72.4], P = 0.02) and remained the same in the RT-CGM group that continued with RT-CGM (65.9 [54.1–74.8] vs. 64.9 [49.2–73.9], P = 0.64).
Conclusions: Our data suggest that switching from flash to RT-CGM has a significant beneficial impact on hypoglycemia outcomes and that continued use of RT-CGM maintains hypoglycemia risk benefit in this high-risk population.
Methods: Prospective randomized parallel group study with an extension phase. After a 2-week run-in with blinded CGM, participants were randomized to either RT-CGM or flash for 8 weeks. All participants were then given the option to continue with RT-CGM for another 8 weeks. Glycemic outcomes at 8 weeks are compared with the 16-week endpoint.
Results: Forty adults with T1D on intensified multiple daily insulin injections and with impaired awareness of hypoglycemia or a recent episode of severe hypoglycemia were included (40% female, median [IQR] age 49.5 [37.5–63.5] years, diabetes duration 30.0 [21.0–36.5] years, HbA1c 56 [48–63] mmol/mol, and Gold Score 5 [4–5]), of whom 36 completed the final 16-week extension. There was a significant reduction in percentage time in hypoglycemia (<3.0 mmol/L) in the group switching from flash to RT-CGM (from 5.0 [3.7–8.6]% to 0.8 [0.4–1.9]%, P = 0.0001), whereas no change was observed in the RT-CGM group continuing with the additional 8 weeks of RT-CGM (1.3 [0.4–2.8] vs. 1.3 [0.8–2.5], P = 0.82). Time in target (3.9–10 mmol/L) increased in the flash group after switching to RT-CGM (60.0 [54.5–67.8] vs. 67.4 [56.3–72.4], P = 0.02) and remained the same in the RT-CGM group that continued with RT-CGM (65.9 [54.1–74.8] vs. 64.9 [49.2–73.9], P = 0.64).
Conclusions: Our data suggest that switching from flash to RT-CGM has a significant beneficial impact on hypoglycemia outcomes and that continued use of RT-CGM maintains hypoglycemia risk benefit in this high-risk population.
Date Issued
2018-10-25
Date Acceptance
2018-09-01
Citation
Diabetes Technology and Therapeutics, 2018, 20 (11), pp.751-757
ISSN
1520-9156
Publisher
Mary Ann Liebert
Start Page
751
End Page
757
Journal / Book Title
Diabetes Technology and Therapeutics
Volume
20
Issue
11
Copyright Statement
© Monika Reddy, et al., 2018; Published by Mary Ann Liebert, Inc. This Open Access article is distributed under the terms of theCreative Commons License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction inany medium, provided the original work is properly credited.
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000445868800001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Subjects
Science & Technology
Life Sciences & Biomedicine
Endocrinology & Metabolism
Continuous Glucose monitoring
Flash glucose monitoring
Type 1 diabetes
Hypoglycemia
RANDOMIZED CONTROLLED-TRIAL
IMPAIRED AWARENESS
INSULIN INJECTIONS
MORTALITY
MULTICENTER
SYSTEMS
Publication Status
Published
Date Publish Online
2018-09-28