Usability study of pH strips for nasogastric tube placement
File(s) journal.pone.0189013.pdf (5.72 MB)
Published version
Author(s)
Type
Journal Article
Abstract
Aims
(1) To model the process of use and usability of pH strips (2) to identify, through simulation studies, the likelihood of misreading pH strips, and to assess professional’s acceptance, trust and perceived usability of pH strips.
Methods
This study was undertaken in four phases and used a mixed method approach (an audit, a semi-structured interview, a survey and simulation study). The three months audit was of 24 patients, the semi-structured interview was performed with 19 health professionals and informed the process of use of pH strips. A survey of 134 professionals and novices explored the likelihood of misinterpreting pH strips. Standardised questionnaires were used to assess professionals perceived usability, trust and acceptance of pH strip use in a simulated study.
Results
The audit found that in 45.7% of the cases aspiration could not be achieved, and that 54% of the NG-tube insertions required x-ray confirmation. None of those interviewed had received formal training on pH strips use. In the simulated study, participants made up to 11.15% errors in reading the strips with important implications for decision making regarding NG tube placement. No difference was identified between professionals and novices in their likelihood of misinterpreting the pH value of the strips. Whilst the overall experience of usage is poor (47.3%), health professionals gave a positive level of trust in both the interview (62.6%) and the survey (68.7%) and acceptance (interview group 65.1%, survey group 74.7%). They also reported anxiety in the use of strips (interview group 29.7%, survey group 49.7%).
Conclusions
Significant errors occur when using pH strips in a simulated study. Manufacturers should consider developing new pH strips, specifically designed for bedside use, that are more usable and less likely to be misread.
(1) To model the process of use and usability of pH strips (2) to identify, through simulation studies, the likelihood of misreading pH strips, and to assess professional’s acceptance, trust and perceived usability of pH strips.
Methods
This study was undertaken in four phases and used a mixed method approach (an audit, a semi-structured interview, a survey and simulation study). The three months audit was of 24 patients, the semi-structured interview was performed with 19 health professionals and informed the process of use of pH strips. A survey of 134 professionals and novices explored the likelihood of misinterpreting pH strips. Standardised questionnaires were used to assess professionals perceived usability, trust and acceptance of pH strip use in a simulated study.
Results
The audit found that in 45.7% of the cases aspiration could not be achieved, and that 54% of the NG-tube insertions required x-ray confirmation. None of those interviewed had received formal training on pH strips use. In the simulated study, participants made up to 11.15% errors in reading the strips with important implications for decision making regarding NG tube placement. No difference was identified between professionals and novices in their likelihood of misinterpreting the pH value of the strips. Whilst the overall experience of usage is poor (47.3%), health professionals gave a positive level of trust in both the interview (62.6%) and the survey (68.7%) and acceptance (interview group 65.1%, survey group 74.7%). They also reported anxiety in the use of strips (interview group 29.7%, survey group 49.7%).
Conclusions
Significant errors occur when using pH strips in a simulated study. Manufacturers should consider developing new pH strips, specifically designed for bedside use, that are more usable and less likely to be misread.
Date Issued
2017-11-30
Date Acceptance
2017-11-16
Citation
PLoS ONE, 2017, 12 (11), pp.1-14
ISSN
1932-6203
Publisher
Public Library of Science (PLoS)
Start Page
1
End Page
14
Journal / Book Title
PLoS ONE
Volume
12
Issue
11
Copyright Statement
© 2017 Borsci et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
License URL
Sponsor
Technology Strategy Board
Grant Number
102134
Subjects
MD Multidisciplinary
General Science & Technology
Publication Status
Published
Article Number
e0189013
Date Publish Online
2017-11-30