Utilizing a wireless radar framework in combination with deep learning approaches to evaluate obstructive sleep apnea severity in home-setting environments
File(s)
Author(s)
Type
Journal Article
Abstract
Objective: Common examinations for diagnosing obstructive sleep apnea (OSA) are polysomnography (PSG) and home sleep apnea testing (HSAT). However, both PSG and HSAT require that sensors be attached to a subject, which may disturb their sleep and affect the results. Hence, in this study, we aimed to verify a wireless radar framework combined with deep learning techniques to screen for the risk of OSA in home-based environments.
Methods: This study prospectively collected home-based sleep parameters from 80 participants over 147 nights using both HSAT and a 24-GHz wireless radar framework. The proposed framework, using hybrid models (ie, deep neural decision trees), identified respiratory events by analyzing continuous-wave signals indicative of breathing patterns. Analyses were performed to examine correlations and agreement of the apnea-hypopnea index (AHI) with results obtained through HSAT and the radar-based respiratory disturbance index based on the time in bed from HSAT (bRDITIB). Additionally, Youden’s index was used to establish cutoff thresholds for the bRDITIB, followed by multiclass classification and outcome comparisons.
Results: A strong correlation (ρ = 0.87) and high agreement (93.88% within the 95% confidence interval; 138/147) between the AHI and bRDITIB were identified. The moderate-to-severe OSA model achieved 83.67% accuracy (with a bRDITIB cutoff of 21.19 events/h), and the severe OSA model demonstrated 93.21% accuracy (with a bRDITIB cutoff of 28.14 events/h). The average accuracy of multiclass classification using these thresholds was 78.23%.
Conclusion: The proposed framework, with its cutoff thresholds, has the potential to be applied in home settings as a surrogate for HSAT, offering acceptable accuracy in screening for OSA without the interference of attached sensors. However, further optimization and verification of the radar-based total sleep time function are necessary for independent application.
Methods: This study prospectively collected home-based sleep parameters from 80 participants over 147 nights using both HSAT and a 24-GHz wireless radar framework. The proposed framework, using hybrid models (ie, deep neural decision trees), identified respiratory events by analyzing continuous-wave signals indicative of breathing patterns. Analyses were performed to examine correlations and agreement of the apnea-hypopnea index (AHI) with results obtained through HSAT and the radar-based respiratory disturbance index based on the time in bed from HSAT (bRDITIB). Additionally, Youden’s index was used to establish cutoff thresholds for the bRDITIB, followed by multiclass classification and outcome comparisons.
Results: A strong correlation (ρ = 0.87) and high agreement (93.88% within the 95% confidence interval; 138/147) between the AHI and bRDITIB were identified. The moderate-to-severe OSA model achieved 83.67% accuracy (with a bRDITIB cutoff of 21.19 events/h), and the severe OSA model demonstrated 93.21% accuracy (with a bRDITIB cutoff of 28.14 events/h). The average accuracy of multiclass classification using these thresholds was 78.23%.
Conclusion: The proposed framework, with its cutoff thresholds, has the potential to be applied in home settings as a surrogate for HSAT, offering acceptable accuracy in screening for OSA without the interference of attached sensors. However, further optimization and verification of the radar-based total sleep time function are necessary for independent application.
Date Issued
2025-01-23
Date Acceptance
2025-01-04
Citation
Journal of Multidisciplinary Healthcare, 2025, 18, pp.381-393
ISSN
1178-2390
Publisher
Dove Medical Press
Start Page
381
End Page
393
Journal / Book Title
Journal of Multidisciplinary Healthcare
Volume
18
Copyright Statement
© 2025 Lee et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
License URL
Publication Status
Published
Date Publish Online
2025-01-23
