Automatic 3D bi-ventricular segmentation of cardiac images by a shape-refined multi-task deep learning approach
File(s)08624549.pdf (9.75 MB)
Accepted version
Author(s)
Type
Journal Article
Abstract
Deep learning approaches have achieved state-of-the-art performance in
cardiac magnetic resonance (CMR) image segmentation. However, most approaches have focused on learning image intensity features for segmentation, whereas the incorporation of anatomical shape priors has received less attention. In this paper, we combine a multi-task deep learning approach with atlas propagation to develop a shape-constrained bi-ventricular segmentation pipeline for short-axis CMR volumetric images. The pipeline first employs a fully convolutional network (FCN) that learns segmentation and landmark localisation tasks simultaneously. The architecture of the proposed FCN uses a 2.5D representation, thus combining the computational advantage of 2D FCNs networks and the capability of addressing 3D spatial consistency without compromising segmentation accuracy. Moreover, the refinement step is designed to explicitly enforce a shape constraint and improve segmentation quality. This step is effective for overcoming image artefacts (e.g. due to different breath-hold positions and large slice thickness), which preclude the creation of anatomically meaningful 3D cardiac shapes. The proposed pipeline is fully automated, due to network's ability to infer landmarks, which are then used downstream in the pipeline to initialise atlas propagation. We validate the pipeline on 1831 healthy subjects and 649 subjects with pulmonary hypertension. Extensive numerical experiments on the two datasets demonstrate that our proposed method is robust and capable of producing accurate, high-resolution and anatomically smooth bi-ventricular
3D models, despite the artefacts in input CMR volumes.
cardiac magnetic resonance (CMR) image segmentation. However, most approaches have focused on learning image intensity features for segmentation, whereas the incorporation of anatomical shape priors has received less attention. In this paper, we combine a multi-task deep learning approach with atlas propagation to develop a shape-constrained bi-ventricular segmentation pipeline for short-axis CMR volumetric images. The pipeline first employs a fully convolutional network (FCN) that learns segmentation and landmark localisation tasks simultaneously. The architecture of the proposed FCN uses a 2.5D representation, thus combining the computational advantage of 2D FCNs networks and the capability of addressing 3D spatial consistency without compromising segmentation accuracy. Moreover, the refinement step is designed to explicitly enforce a shape constraint and improve segmentation quality. This step is effective for overcoming image artefacts (e.g. due to different breath-hold positions and large slice thickness), which preclude the creation of anatomically meaningful 3D cardiac shapes. The proposed pipeline is fully automated, due to network's ability to infer landmarks, which are then used downstream in the pipeline to initialise atlas propagation. We validate the pipeline on 1831 healthy subjects and 649 subjects with pulmonary hypertension. Extensive numerical experiments on the two datasets demonstrate that our proposed method is robust and capable of producing accurate, high-resolution and anatomically smooth bi-ventricular
3D models, despite the artefacts in input CMR volumes.
Date Issued
2019-09
Date Acceptance
2019-01-01
Citation
IEEE Transactions on Medical Imaging, 2019, 38 (9), pp.2151-2164
ISSN
0278-0062
Publisher
Institute of Electrical and Electronics Engineers
Start Page
2151
End Page
2164
Journal / Book Title
IEEE Transactions on Medical Imaging
Volume
38
Issue
9
Copyright Statement
© 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see http://creativecommons.org/licenses/by/4.0/
License URL
Sponsor
Imperial College London
British Heart Foundation
Engineering & Physical Science Research Council (EPSRC)
Imperial College Healthcare NHS Trust- BRC Funding
Imperial College Healthcare NHS Trust- BRC Funding
Engineering & Physical Science Research Council (EPSRC)
Identifier
http://arxiv.org/abs/1808.08578v2
Grant Number
NH/17/1/32725
EP/P001009/1
RDC04
RDB02
EP/K030523/1
Subjects
cs.CV
cs.CV
cs.AI
Publication Status
Published
Date Publish Online
2019-01-23