Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis
Author(s)
Type
Journal Article
Abstract
Background
Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings.
Methods and results
Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4°C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy.
Conclusions
We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings.
Methods and results
Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4°C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy.
Conclusions
We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
Date Issued
2019-04-30
Date Acceptance
2019-03-07
Citation
PLoS One, 2019, 14 (4), pp.1-24
ISSN
1932-6203
Publisher
Public Library of Science (PLoS)
Start Page
1
End Page
24
Journal / Book Title
PLoS One
Volume
14
Issue
4
Copyright Statement
© 2019 Datta et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
License URL
Sponsor
Medical Research Council (MRC)
Wellcome Trust
Wellcome Trust
Wellcome Trust
Imperial Health Charity
Wellcome Trust
Wellcome Trust
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000466364800006&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Grant Number
MR/K007467/1
201251/Z/16/Z
105788/Z/14/Z
097816/Z/11/A
N/A
100693/Z/12/Z
076340/Z/05/Z
Subjects
Science & Technology
Multidisciplinary Sciences
Science & Technology - Other Topics
DIAGNOSIS
INFECTIOUSNESS
Publication Status
Published
Article Number
ARTN e0214131
Date Publish Online