Repository logo
  • Log In
    Log in via Symplectic to deposit your publication(s).
Repository logo
  • Communities & Collections
  • Research Outputs
  • Statistics
  • Log In
    Log in via Symplectic to deposit your publication(s).
  1. Home
  2. Faculty of Engineering
  3. Electrical and Electronic Engineering
  4. Electrical and Electronic Engineering
  5. Improving the detection of cholangiocarcinoma: in vitro MRI-based study using local coils and T2 mapping
 
  • Details
Improving the detection of cholangiocarcinoma: in vitro MRI-based study using local coils and T2 mapping
File(s)
Improving the Detection of Cholangiocarcinoma In vitro MRI-Based Study Using Local Coils and T2 Mapping.pdf (8.17 MB)
Published version
Author(s)
Khuntikeo, Narong
Titapun, Attapol
Chamadol, Nittaya
Boonphongsathien, Wuttisak
Sa-Ngiamwibool, Prakasit
more
Type
Journal Article
Abstract
Aim: Cholangiocarcinoma is endemic in southeast Asia, generally developing from liver fluke infestation. However, diagnostic imaging of early-stage disease is challenging. The aim of this work is to investigate relaxometry (specifically, T2 mapping) as a method of exploiting the higher signal-to-noise ratio (SNR) of internal coils for improved reception of magnetic resonance signals, despite their non-uniform sensitivity.
Methods: Ex vivo T2 mapping was carried out at 3T on fixed resection specimens from Thai cholangiocarcinoma patients using an mGRASE sequence and an endoscope coil based on a thin-film magneto-inductive waveguide and designed ultimately for internal use.
Results: Disease-induced changes including granulomatous inflammation, intraepithelial neoplasia and intraductal tumours were correlated with histopathology, and relaxation data were compared with mono- and bi-exponential models of T2 relaxation. An approximately 10-fold local advantage in SNR compared to a 16-element torso coil was demonstrated using the endoscope coil, and improved tissue differentiation was obtained without contrast agents.
Conclusion: The performance advantage above follows directly from the inverse relation between the component of the standard deviation of T2 due to thermal noise and the SNR, and offers an effective method of exploiting the SNR advantage of internal coils. No correction is required, avoiding the need for tracking, relaxing constraints on coil and slice orientation and providing rapid visualization.
Date Issued
2020-03-24
Date Acceptance
2020-02-20
Citation
Hepatic Medicine : Evidence and Research, 2020, 12, pp.29-39
URI
http://hdl.handle.net/10044/1/80108
URL
https://www.dovepress.com/improving-the-detection-of-cholangiocarcinoma-in-vitro-mri-based-study-peer-reviewed-article-HMER
DOI
https://www.dx.doi.org/10.2147/HMER.S232392
ISSN
1179-1535
Publisher
Dove Medical Press
Start Page
29
End Page
39
Journal / Book Title
Hepatic Medicine : Evidence and Research
Volume
12
Copyright Statement
© 2020 Khuntikeo et al. This work is published by Dove Medical Press Limited, and licensed under a Creative Commons Attribution License. The full terms of the License
are available at http://creativecommons.org/licenses/by/4.0/. The license permits unrestricted use, distribution, and reproduction in any medium, provided the original
author and source are credited.
Sponsor
Wellcome Trust
Wellcome Trust
Wellcome Trust
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000522457700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Grant Number
097816/Z/11/ZR
097816/Z/11/A
097816/Z/11/B
Subjects
Science & Technology
Life Sciences & Biomedicine
Gastroenterology & Hepatology
cholangiocarcinoma
T2 mapping
internal coil
INTRAHEPATIC CHOLANGIOCARCINOMA
RELAXATION-TIMES
RESONANCE
CLASSIFICATION
MORTALITY
Publication Status
Published
Date Publish Online
2020-03-24
About
Spiral Depositing with Spiral Publishing with Spiral Symplectic
Contact us
Open access team Report an issue
Other Services
Scholarly Communications Library Services
logo

Imperial College London

South Kensington Campus

London SW7 2AZ, UK

tel: +44 (0)20 7589 5111

Accessibility Modern slavery statement Cookie Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback