Aims
The diagnostic performance of quantitative perfusion cardiac magnetic resonance (QP-CMR) imaging has scarcely been evaluated in patients with a history of coronary artery disease (CAD) and new onset chest pain. The present study compared the diagnostic performance of automated QP-CMR for detection of fractional flow reserve (FFR) defined hemodynamically significant CAD with visual assessment of first-pass stress perfusion CMR (v-CMR) and quantitative [15O]H2O positron emission tomography (PET) imaging in a true head-to-head fashion in patients with prior CAD.
Methods and results
This PACIFIC-2 substudy included 145 symptomatic chronic coronary symptom patients with prior myocardial infarction (MI) and/or percutaneous coronary intervention (PCI). All patients underwent dual-sequence, single bolus perfusion CMR and [15O]H2O PET perfusion imaging followed by invasive coronary angiography with three-vessel FFR. Hemodynamically significant CAD was defined as an FFR ≤0.80. QP-CMR, v-CMR and PET exhibited a sensitivity of 66%, 67%, and 80%, respectively, whereas specificity was 60%, 62%, and 63%. Sensitivity of QP-CMR was lower than PET (P=0.015), whereas specificity of QP-CMR and PET was comparable. Diagnostic accuracy and area under the curve (AUC) of QP-CMR (64% and 0.66) was comparable to both v-CMR (66% [P=NS] and 0.67 (P=NS]) and PET (74% [P=NS] and 0.78 [P=NS]).
Conclusions
In patients with prior MI and/or PCI, the diagnostic performance of QP-CMR was comparable to visual assessment of first-pass stress perfusion CMR and quantitative [15O]H2O PET for the detection of hemodynamically significant CAD as defined by FFR.
The diagnostic performance of quantitative perfusion cardiac magnetic resonance (QP-CMR) imaging has scarcely been evaluated in patients with a history of coronary artery disease (CAD) and new onset chest pain. The present study compared the diagnostic performance of automated QP-CMR for detection of fractional flow reserve (FFR) defined hemodynamically significant CAD with visual assessment of first-pass stress perfusion CMR (v-CMR) and quantitative [15O]H2O positron emission tomography (PET) imaging in a true head-to-head fashion in patients with prior CAD.
Methods and results
This PACIFIC-2 substudy included 145 symptomatic chronic coronary symptom patients with prior myocardial infarction (MI) and/or percutaneous coronary intervention (PCI). All patients underwent dual-sequence, single bolus perfusion CMR and [15O]H2O PET perfusion imaging followed by invasive coronary angiography with three-vessel FFR. Hemodynamically significant CAD was defined as an FFR ≤0.80. QP-CMR, v-CMR and PET exhibited a sensitivity of 66%, 67%, and 80%, respectively, whereas specificity was 60%, 62%, and 63%. Sensitivity of QP-CMR was lower than PET (P=0.015), whereas specificity of QP-CMR and PET was comparable. Diagnostic accuracy and area under the curve (AUC) of QP-CMR (64% and 0.66) was comparable to both v-CMR (66% [P=NS] and 0.67 (P=NS]) and PET (74% [P=NS] and 0.78 [P=NS]).
Conclusions
In patients with prior MI and/or PCI, the diagnostic performance of QP-CMR was comparable to visual assessment of first-pass stress perfusion CMR and quantitative [15O]H2O PET for the detection of hemodynamically significant CAD as defined by FFR.
Date Issued
2025-02-01
Date Acceptance
2024-09-20
Citation
European Heart Journal - Cardiovascular Imaging, 2025, 26 (2), pp.207-217
ISSN
2047-2404
Publisher
Oxford University Press (OUP)
Start Page
207
End Page
217
Journal / Book Title
European Heart Journal - Cardiovascular Imaging
Volume
26
Issue
2
Copyright Statement
© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License
(https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and
reproduction in any medium, provided the original work is properly cited.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License
(https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and
reproduction in any medium, provided the original work is properly cited.
License URL
Identifier
http://dx.doi.org/10.1093/ehjci/jeae262
Publication Status
Published
Article Number
jeae262
Date Publish Online
2024-10-09