Background
The adoption of C-reactive protein point-of-care tests (CRP POCTs) in hospitals varies across Europe. We aimed to understand the factors that contribute to different levels of adoption of CRP POCTs for the management of acute childhood infections in two countries.
Methods
Comparative qualitative analysis of the implementation of CRP POCTs in the Netherlands and England. The study was informed by the non-adoption, abandonment, spread, scale-up, and sustainability (NASSS) framework. Data were collected through document analysis and qualitative interviews with stakeholders. Documents were identified by a scoping literature review, search of websites, and through the stakeholders. Stakeholders were sampled purposively initially, and then by snowballing. Data were analysed thematically.
Results
Forty-one documents resulted from the search and 46 interviews were conducted. Most hospital healthcare workers in the Netherlands were familiar with CRP POCTs as the tests were widely used and trusted in primary care. Moreover, although diagnostics were funded through similar Diagnosis Related Group reimbursement mechanisms in both countries, the actual funding for each hospital was more constrained in England. Compared to primary care, laboratory-based CRP tests were usually available in hospitals and their use was encouraged in both countries because they were cheaper. However, CRP POCTs were perceived as useful in some hospitals of the two countries in which the laboratory could not provide CRP measures 24/7 or within a short timeframe, and/or in emergency departments where expediting patient care was important.
Conclusions
CRP POCTs are more available in hospitals in the Netherlands because of the greater familiarity of Dutch healthcare workers with the tests which are widely used in primary care in their country and because there are more funding constraints in England. However, most hospitals in the Netherlands and England have not adopted CRP POCTs because the alternative CRP measurements from the hospital laboratory are available in a few hours and at a lower cost.
The adoption of C-reactive protein point-of-care tests (CRP POCTs) in hospitals varies across Europe. We aimed to understand the factors that contribute to different levels of adoption of CRP POCTs for the management of acute childhood infections in two countries.
Methods
Comparative qualitative analysis of the implementation of CRP POCTs in the Netherlands and England. The study was informed by the non-adoption, abandonment, spread, scale-up, and sustainability (NASSS) framework. Data were collected through document analysis and qualitative interviews with stakeholders. Documents were identified by a scoping literature review, search of websites, and through the stakeholders. Stakeholders were sampled purposively initially, and then by snowballing. Data were analysed thematically.
Results
Forty-one documents resulted from the search and 46 interviews were conducted. Most hospital healthcare workers in the Netherlands were familiar with CRP POCTs as the tests were widely used and trusted in primary care. Moreover, although diagnostics were funded through similar Diagnosis Related Group reimbursement mechanisms in both countries, the actual funding for each hospital was more constrained in England. Compared to primary care, laboratory-based CRP tests were usually available in hospitals and their use was encouraged in both countries because they were cheaper. However, CRP POCTs were perceived as useful in some hospitals of the two countries in which the laboratory could not provide CRP measures 24/7 or within a short timeframe, and/or in emergency departments where expediting patient care was important.
Conclusions
CRP POCTs are more available in hospitals in the Netherlands because of the greater familiarity of Dutch healthcare workers with the tests which are widely used in primary care in their country and because there are more funding constraints in England. However, most hospitals in the Netherlands and England have not adopted CRP POCTs because the alternative CRP measurements from the hospital laboratory are available in a few hours and at a lower cost.
Date Issued
2024-03-19
Date Acceptance
2024-02-08
Citation
BMC Health Services Research, 2024, 24
ISSN
1472-6963
Publisher
BMC
Journal / Book Title
BMC Health Services Research
Volume
24
Copyright Statement
© The Author(s) 2024. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which
permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the
original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or
other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line
to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory
regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this
licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the
original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or
other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line
to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory
regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this
licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
License URL
Identifier
http://dx.doi.org/10.1186/s12913-024-10698-6
Publication Status
Published
Article Number
351
Date Publish Online
2024-03-19