Abstract
Aims The Venous External Support Trial (VEST) evaluated whether a novel external stent attenuated saphenous vein graft (SVG) disease assessed with intravascular ultrasound 1 year following coronary artery bypass graft (CABG) surgery. This sub-study assessed SVGs with and without external stenting using optical coherence tomography (OCT). The aim of this study was to accurately compare quantitative and qualitative features of SVGs with and without a novel external stent using OCT.
Methods and results Twenty-four of 30 patients (65 ± 8 years) enrolled in VEST underwent coronary angiography with OCT imaging using a non-occlusive technique. Quantitative analysis of lumen area was performed in one frame every 10 mm along the length of the graft, from distal to proximal anastomosis, and pathological features within the lumen were noted. Mean cross-sectional area was greater in unstented vs. stented grafts (8.4 ± 3 vs. 7.6 ± 2.7 mm; P = 0.005). The lumen of the stented grafts was more homogeneous (difference between maximum and minimum lumen diameter was significantly smaller in stented compared with unstented grafts, 0.28 ± 0.19 vs. 0.33 ± 0.23 mm, respectively, P = 0.006), and more circular (mean eccentricity index 0.08 ± 0.06 vs. 0.10 ± 0.06, stented vs. unstented; P = 0.019). Adherent thrombus was identified in three grafts (all unstented).
Conclusion Our findings highlight the early changes occurring in SVGs after implantation of aorto-coronary bypass conduits, changes that may accelerate vein graft failure. External stenting resulted in a more homogeneous and less eccentric lumen with no thrombus formation.
Methods and results Twenty-four of 30 patients (65 ± 8 years) enrolled in VEST underwent coronary angiography with OCT imaging using a non-occlusive technique. Quantitative analysis of lumen area was performed in one frame every 10 mm along the length of the graft, from distal to proximal anastomosis, and pathological features within the lumen were noted. Mean cross-sectional area was greater in unstented vs. stented grafts (8.4 ± 3 vs. 7.6 ± 2.7 mm; P = 0.005). The lumen of the stented grafts was more homogeneous (difference between maximum and minimum lumen diameter was significantly smaller in stented compared with unstented grafts, 0.28 ± 0.19 vs. 0.33 ± 0.23 mm, respectively, P = 0.006), and more circular (mean eccentricity index 0.08 ± 0.06 vs. 0.10 ± 0.06, stented vs. unstented; P = 0.019). Adherent thrombus was identified in three grafts (all unstented).
Conclusion Our findings highlight the early changes occurring in SVGs after implantation of aorto-coronary bypass conduits, changes that may accelerate vein graft failure. External stenting resulted in a more homogeneous and less eccentric lumen with no thrombus formation.
Date Issued
2015-11-30
Date Acceptance
2015-10-28
Citation
European Heart Journal Cardiovascular Imaging
ISSN
2047-2412
Publisher
Oxford University Press (OUP): Policy B - Oxford Open Option B - CC-BY
Start Page
1290
End Page
1295
Journal / Book Title
European Heart Journal Cardiovascular Imaging
Volume
17
Copyright Statement
© 2015 Oxford University Press. This is a pre-copy-editing, author-produced PDF of an article accepted for publication in European Heart Journal - Cardiovascular Imaging following peer review. The definitive publisher-authenticated version is available online at: http://dx.doi.org/10.1093/ehjci/jev310
Identifier
PII: jev310
Subjects
bypass
imaging
stents
surgery
veins
Publication Status
Published