Abstract
Introduction
Little is known about the bloodstream infection (BSI) risk associated with short-term peripheral venous catheters (PVCs) and no large study investigated the insertion site-related risk for PVC-BSI.
Methods
We performed a cohort study at the University of Geneva Hospitals using the prospective hospital-wide BSI surveillance database. We analyzed the association between insertion site and risk of PVC-BSI on the upper extremity using univariable and multivariable marginal Cox models.
Results
Between 2016 and 2020, utilization of 403′206 peripheral venous catheters were prospectively recorded in a 2000-bed hospital consortium with ten sites. Twenty-seven percent of PVC (n = 109′686) were inserted in the hand. After adjustment for confounding factors, hand insertion was associated with a decreased PVC-BSI risk (adjusted hazard ratio [HR] 0.42, 95% CI 0.18–0.98, p = 0.046) compared to more proximal insertion sites. In a sensitivity analysis for PVCs with ≥ 3 days of dwell time, we confirmed a decreased PVC-BSI risk after hand insertion (HR 0.37, 95% CI 0.15–0.93, p = 0.035).
Conclusion
Hand insertion should be considered for reducing PVC infections, especially for catheters with an expected dwell time of more than 2 days.
Little is known about the bloodstream infection (BSI) risk associated with short-term peripheral venous catheters (PVCs) and no large study investigated the insertion site-related risk for PVC-BSI.
Methods
We performed a cohort study at the University of Geneva Hospitals using the prospective hospital-wide BSI surveillance database. We analyzed the association between insertion site and risk of PVC-BSI on the upper extremity using univariable and multivariable marginal Cox models.
Results
Between 2016 and 2020, utilization of 403′206 peripheral venous catheters were prospectively recorded in a 2000-bed hospital consortium with ten sites. Twenty-seven percent of PVC (n = 109′686) were inserted in the hand. After adjustment for confounding factors, hand insertion was associated with a decreased PVC-BSI risk (adjusted hazard ratio [HR] 0.42, 95% CI 0.18–0.98, p = 0.046) compared to more proximal insertion sites. In a sensitivity analysis for PVCs with ≥ 3 days of dwell time, we confirmed a decreased PVC-BSI risk after hand insertion (HR 0.37, 95% CI 0.15–0.93, p = 0.035).
Conclusion
Hand insertion should be considered for reducing PVC infections, especially for catheters with an expected dwell time of more than 2 days.
Date Issued
2022-12
Date Acceptance
2022-05-20
Citation
Antimicrobial Resistance and Infection Control, 2022, 11 (1)
ISSN
2047-2994
Publisher
BioMed Central
Journal / Book Title
Antimicrobial Resistance and Infection Control
Volume
11
Issue
1
Copyright Statement
© The Author(s) 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which
permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the
original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or
other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line
to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory
regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this
licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativeco
mmons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the
original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or
other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line
to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory
regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this
licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativeco
mmons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
License URL
Identifier
https://aricjournal.biomedcentral.com/articles/10.1186/s13756-022-01117-8
Subjects
0605 Microbiology
1103 Clinical Sciences
1108 Medical Microbiology
Publication Status
Published online
Article Number
80
Date Publish Online
2022-06-03