Use of bioresorbable vascular scaffold: a meta-analysis of patients with coronary artery disease.
File(s) Open Heart-2016-Farag-.pdf (2 MB)
Published version
Author(s)
Type
Journal Article
Abstract
BACKGROUND: Differences in outcomes between bioresorbable vascular scaffold (BVS) systems and drug-eluting metal stents (DES) have not been fully evaluated. We aimed to compare clinical and angiographic outcomes in randomised studies of patients with coronary artery disease (CAD), with a secondary analysis performed among registry studies. METHODS: A meta-analysis comparing outcomes between BVS and DES in patients with CAD. Overall estimates of treatment effect were calculated with random-effects model and fixed-effects model. RESULTS: In 6 randomised trials (3818 patients), BVS increased the risk of subacute stent thrombosis (ST) over and above DES (OR 2.14; CI 1.01 to 4.53; p=0.05), with a trend towards an increase in the risk of myocardial infarction (MI) (125 events in those assigned to BVS and 50 to DES; OR 1.36; CI 0.97 to 1.91; p=0.07). The risk of in-device late lumen loss (LLL) was higher with BVS than DES (mean difference 0.08 mm; CI 0.03 to 0.13; p=0.004). There was no difference in the risk of death or target vessel revascularisation (TVR) between the two devices. In 6 registry studies (1845 patients), there was no difference in the risk of death, MI, TVR or subacute ST between the two stents. Final BVS dilation pressures were higher in registry than in randomised studies (18.7±4.6 vs 15.2±3.3 atm; p<0.001). CONCLUSIONS: Patients treated with BVS had an increased risk of subacute ST and slightly higher LLL compared with those with DES, but this might be related to inadequate implantation techniques, in particular device underexpansion.
Date Issued
2016-08-26
Date Acceptance
2016-07-24
Citation
Open Heart, 2016, 3 (2), pp.e000462-e000462
ISSN
2053-3624
Publisher
BMJ Publishing Group
Start Page
e000462
End Page
e000462
Journal / Book Title
Open Heart
Volume
3
Issue
2
Copyright Statement
This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
License URL
Identifier
PII: openhrt-2016-000462
Subjects
CORONARY ARTERY DISEASE
bioresorbable scaffold
drug-eluting stent
percutaneous coronary intervention
Publication Status
Published
