Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study
Author(s)
Type
Journal Article
Abstract
Background and purpose
Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients.
Material and methods
Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty.
Results
Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance.
Conclusion
Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance.
Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA) lung cancer patients.
Material and methods
Twenty-two cine MRI sequences were acquired using either a balanced steady-state free precession or a spoiled gradient echo imaging technique. Contours derived by the auto-contouring algorithms were compared against manual reference contours. A selection of eight image data sets was also used to assess the inter-observer delineation uncertainty.
Results
Algorithmically derived contours agreed well with the manual reference contours (median Dice similarity index: ). Multi-template matching and deformable image registration performed significantly better than feature-driven registration and the pulse-coupled neural network (PCNN). Neither MRI sequence nor image orientation was a conclusive predictor for algorithmic performance. Motion significantly degraded the performance of the PCNN. The inter-observer variability was of the same order of magnitude as the algorithmic performance.
Conclusion
Auto-contouring of tumours on cine MRI is feasible in LA lung cancer patients. Despite large variations in implementation complexity, the different algorithms all have relatively similar performance.
Date Issued
2017-12-01
Date Acceptance
2017-09-13
Citation
Radiotherapy and Oncology, 2017, 125 (3), pp.485-491
ISSN
0167-8140
Publisher
Elsevier
Start Page
485
End Page
491
Journal / Book Title
Radiotherapy and Oncology
Volume
125
Issue
3
Copyright Statement
© 2017 The Author(s). Published by Elsevier Ireland Ltd.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Identifier
http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000423246300018&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
Subjects
Science & Technology
Life Sciences & Biomedicine
Oncology
Radiology, Nuclear Medicine & Medical Imaging
Lung tumour tracking
Auto-contouring
MRI-guided radiotherapy
Locally advanced lung cancer
GUIDED RADIATION-THERAPY
AUTOCONTOURING ALGORITHM
NONRIGID REGISTRATION
LINAC-MR
TRACKING
RADIOTHERAPY
IMAGES
MOTION
SYSTEM
SEQUENCES
Publication Status
Published
Date Publish Online
2017-10-10